Penanggulangan Transformator Distribusi Berbeban Lebih Dengan Metode Sisip Trafo Pada Penyulang PW-02 PT PLN (Persero) ULP Subulussalam Kota

Penulis

  • Filia Berkat Nanda Lumbantobing Universitas Pembangunan Panca Budi
  • Hamdani Universitas Pembangunan Panca Budi

Kata Kunci:

Transformer, Insertion Transformer, Overload.

Abstrak

Distribution transformer is one of the most important components in the distribution of electric power from distribution substations to customers. Distribution transformers that experience loads exceeding 80% of the transformer capacity will affect the life of the distribution transformer and can also affect the level and quality of service to consumers and have the potential for disruption. Therefore, it is necessary to take action so that the percentage of distribution transformer loading does not exceed the transformer capacity by installing an Insert Transformer. At PT. PLN (Persero) ULP SUBULUSSALAM KOTA, there is a transformer that experiences overloading that occurs at the SKI072-00 Distribution Substation of 96.016% and after the Insert Transformer is installed, the loading at the SKI072-00 substation becomes 43.27%. This proves that the installation of an Insert Transformer is a fairly good method for overcoming overload disturbances at the SKI072-00 Substation, so that it can extend the life of the transformer, improve the quality of service to customers and reduce the potential for disturbances because the transformer loading below 80% can work well.

Unduhan

Data unduhan belum tersedia.

Referensi

Ayu, Minar Grace. 2015. Studi Penanggulangan Transformator Berbeban Lebih pada jaringanDistribusi Tegangan Rendah Daerah Kerja PT. PLN (Persero) Area MedanRayon Medan Timur. Medan: Polmed.

Fatmawati, A. 2020. Studi Pembebanan Transformator Distribusi TIpe Voltra 100 Kva. Politeknik Bosowa, Makassar.

Samsurizal, Benyamin Hadinoto (2020). Studi Analisis Dampak Overload Transformator Terhadap Kualitas Daya Di PT. PLN (Persero) UP3 Pondok Gede. Vol. 9 No. 1 tahun 2020, Redaksi Kilat, 139

Widiatmika, K. W., Wijaya, I. A., & Setaiawan, I. N. (2018). E-Journal SPEKTRUM. Analisa Penambahan Transfromator Sisipan Untuk Mengatasi Overload Pada Transfromator DB0244 Di Penyulang Sebelanga, 5(2), 19-25.

Unduhan

Diterbitkan

30-04-2026

Cara Mengutip

Filia Berkat Nanda Lumbantobing, & Hamdani. (2026). Penanggulangan Transformator Distribusi Berbeban Lebih Dengan Metode Sisip Trafo Pada Penyulang PW-02 PT PLN (Persero) ULP Subulussalam Kota. Jurnal Nasional Teknologi Komputer, 6(2), 923–936. Diambil dari https://publikasi.hawari.id/index.php/jnastek/article/view/423