Peningkatan Nilai Sistem Pertanahan Pada Tower Transmisi SUTT 70 kV PLTMG Flores – Labuan Bajo
Kata Kunci:
Grounding, 70 kV SUTT, Counterpoise Method, Stick RodAbstrak
The construction of the 70 kV SUTT Rangko - Labuan Bajo transmission line has faced challenges in the grounding work. According to SPLN T5.012_2020, there are specific grounding requirements for the tower structures and cable parts of SUTT towers. Flores Island has mountainous and hilly terrain, with several active volcanoes, which often results in high and fluctuating soil resistivity. Improving the grounding value at the SUTT 70 kV Rangko - Labuan Bajo towers to meet SPLN T5.012_2020 standards is essential for enhancing the reliability of electrical installations and systems in Flores. Routine maintenance of the grounding system is necessary because it is crucial for protecting tower components, especially during lightning strikes. For the tower grounding improvement, the counterpoise method was used. Initial measurements showed that the grounding resistance at four tower points did not meet the required standard. This paper discusses improving the grounding value at these four towers using the counterpoise method, namely by adding stick rods to each tower leg until the required standard value is met (≤ 3 Ω for the five towers near the substation and a maximum of 10 Ω in other areas).
Unduhan
Referensi
P. P. (Persero) S. T5.012, Pembumian Pada Gardu Induk dan Jaringan Transmisi. Jakarta: PT. PLN (Persero), 2020.
N. Lembang, S. Manjang, and I. Kitta, “Efek Penurunan Tahanan Pembumian Tower 150 kV Terhadap Sistem Penyaluran Petir,” J. Penelit. Enj., vol. 21, no. 2, pp. 7–15, 2018, doi: 10.25042/jpe.112017.02.
B. E. Prasetyo, A. Hermawan, and S. Azizah, “Analisis Perbaikan Sistem Pentanahan Tower 70 kV pada Transmisi Wlingi - Blitar,” Elposys J. Sist. Kelistrikan, vol. 9, no. 3, pp. 205–209, 2023, doi: 10.33795/elposys.v9i3.970.
K. A. N. Ichsan, “Analisis Pengaruh Pentanahan Terhadap Jumlah Isolator Transmisi Sutt Jajar–Pedan,” Doctoral dissertation, Universitas Muhammadiyah Surakarta, 2018.
D. Pranatali, “Analisa Kelayakan Pentanahan Tower Saluran Udara Tegangan Tinggi (SUTT) 150kV Jelok – Bringin Menggunakan Metode Komparasi,” 2022.
Unduhan
Diterbitkan
Cara Mengutip
Terbitan
Bagian
Lisensi

Artikel ini berlisensiCreative Commons Attribution-ShareAlike 4.0 International License.
HAK CIPTA
Hak cipta atas artikel apapun pada Jurnal Nasional Teknologi Komputer (JNASTEK) dipegang penuh oleh penulisnya dibawah lisensi Creative Commons Attribution-ShareAlike 4.0 International License.
1. Penulis mengakui bahwa Jurnal Nasional Teknologi Komputer (JNASTEK) berhak sebagai yang mempublikasikan pertama kali dengan lisensi Creative Commons Attribution-ShareAlike 4.0 International License - CC BY-SA.
2. Penulis dapat memasukan tulisan secara terpisah, mengatur distribusi non-ekskulif dari naskah yang telah terbit di jurnal ini kedalam versi yang lain (misal: dikirim ke respository institusi penulis, publikasi kedalam buku, dll), dengan mengakui bahwa naskah telah terbit pertama kali pada Jurnal Nasional Teknologi Komputer (JNASTEK).
LISENSI
Jurnal Nasional Teknologi Komputer (JNASTEK) diterbitkan berdasarkan ketentuan Creative Commons Attribution-ShareAlike 4.0 International License. Lisensi ini mengizinkan setiap orang untuk menyalin dan menyebarluaskan kembali materi ini dalam bentuk atau format apapun, menggubah, mengubah, dan membuat turunan dari materi ini untuk kepentingan apapun, termasuk kepentingan komersial, selama mereka mencantumkan kredit kepada Penulis atas ciptaan asli.